What do equivalence points mean




















Veena Indian. Priya Indian. Neerja Indian. Zira US English. Oliver British. Wendy British. Fred US English. Tessa South African. How to say equivalence point in sign language? Numerology Chaldean Numerology The numerical value of equivalence point in Chaldean Numerology is: 3 Pythagorean Numerology The numerical value of equivalence point in Pythagorean Numerology is: 8.

Select another language:. Please enter your email address: Subscribe. Discuss these equivalence point definitions with the community: 0 Comments. The endpoint is referred to as the point at which the used indicator changes its color.

These color changes appear after reaching the equivalence point. If we use the endpoint to determine equivalence, it will induce an error. There are different methods for the determination of the equivalence point. They are discussed as follows:. An acid-base indicator, for example, phenolphthalein changes its color which depends on its pH.

Redox indicators can also be used for this purpose. Initially, just a single drop of indicator solution is added to the titration. The change in color will show that the endpoint has been attained. This will be an estimation of the equivalence point. The electrical conductivity of a solution is affected by the ions. Hence the conductivity changes when they react with each other. Conductance is relatively a difficult method to operate, especially when the ions that are present in the solution can participate in conductivity.

Conductance can be used for a few acid-base reactions. At the equivalence point, the solution will change its color naturally without any addition of an indicator in some reactions. This may be observed in transition metals where the oxidation state consists of different colors. During titration, the precipitate will form if the reaction forms a solid.

Unexpectedly, this makes it very hard to determine the endpoints accurately because of particle size, the rate of sedimentation and color makes it very difficult to see.

This is the reason why precipitation titration is done as back titrations. The determination of the equivalence point is done by calculating the amount of heat that is produced or absorbed by using a device known as an isothermal titration calorimeter. This type is usually used in titrations that involve biochemical reactions i. Thermometric titrimetry is an exceptionally multifaceted technique. Here the equivalence point is determined by measuring the rate of temperature change produced by a chemical reaction.

This property differentiates it from calorimetric titrimetry. Because thermometric titrimetry is a relative technique, it is not necessary to perform the titration under isothermal conditions.

More often than not, the color change occurs after the equivalence point has already been reached. Using the endpoint to calculate equivalence naturally introduces error.

There are several different ways to identify the equivalence point of a titration:. Color Change - Some reactions naturally change color at the equivalence point. This may be seen in redox titration, particularly involving transition metals, where the oxidation states have different colors. The indicator dye is added at the beginning of the titration.

The color change at the endpoint is an approximation of the equivalence point. Precipitation - If an insoluble precipitate forms as a result of the reaction, it can be used to determine the equivalence point. For example, the silver cation and chloride anion react to form silver chloride, which is insoluble in water.

However, it can be difficult to determine precipitation because the particle size, color, and sedimentation rate may make it difficult to see. Conductance - Ions affect the electrical conductivity of a solution, so when they react with each other, the conductivity changes. Conductance may be a difficult method to use, especially if other ions are present in the solution that can contribute to its conductivity. Conductance is used for some acid-base reactions. Isothermal Calorimetry - The equivalence point may be determined by measuring the amount of heat that is produced or absorbed using a device called an isothermal titration calorimeter.

This method is often used in titrations involving biochemical reactions, such as enzyme binding. Spectroscopy - Spectroscopy can be used to find the equivalence point if the spectrum of the reactant, product, or titrant is known. This method is used to detect etching of semiconductors. Below are some common equivalence point indicators: You can estimate the equivalence point's pH using the following rules: You can determine the pH of a weak acid solution being titrated with a strong base solution at various points ; these fall into four different categories: 1 initial pH; 2 pH before the equivalence point ; 3 pH at the equivalence point ; and 4 pH after the equivalence point.

The number of equivalents of acid and base must be equal at the equivalence point. Weak Acid-Strong Base Titrations This indicates the formation of a buffer system as the titration approaches the equivalence point. At the equivalence point and beyond, the curve is typical of a titration of, for example, NaOH and HCl.

However, the pH at the equivalence point does not equal 7. The endpoint and the equivalence point are not exactly the same: the equivalence point is determined by the stoichiometry of the reaction, while the endpoint is just the color change from the indicator.

Background and Properties The following table lists some representative derivatives and their boiling points.